Home Laboratory oil analyzer Flash point tester Fully automatic closed cup flash point tester TP611
Multifunctional Digestion Instrument TP508
Back to products
Fully automatic open flash point tester TP612
Click to enlarge

Fully automatic closed cup flash point tester TP611

Brand: TIMEPOWER
Features: The fully automatic closed cup flash point tester is a new generation of fully automatic instrument designed and manufactured according to GB/T261 and ASTM D93 standards.
Application: Used in power, petroleum, chemical, commodity inspection, scientific research departments and oil products that need to measure the flash point characteristics of petroleum products. Suitable for testing the open flash point temperature and hazard level of oil products.

Share:
  • Description
Description

Features

  • 01 Lifting, temperature control, ignition, detection, printing, cooling, etc. are carried out automatically.
  • 02 Heating rate and stirring rate can adapt to various standards.
  • 03 With atmospheric pressure calibration function.
  • 04 The closed cup flash point tester will automatically stop heating when the temperature exceeds the value.
  • 05 The flash point tester has a fault self-diagnosis function.
  • 06 5.0-inch touch display LCD screen, Chinese display.
  • 07 Unique ignition design.
  • 08 Gas flame scanning or electronic flame scanning mode switches automatically.

working principle/ PRINCIPLE

Working principle of closed cup flash point tester TP611

Closed cup flash point tester is a Laboratory oil analyzer , under the conditions specified in national standard GB/T 261, puts the sample into the test cup, heats the test cup containing the test oil, and the lowest temperature of the condensed synthetic gas formed by the generated petroleum vapor and the surrounding air when it contacts the flame and flashes are taken as the flash point. The instrument controls the heater according to the collected temperature changes so that the temperature of the test oil rises at a certain rate. When the flash is detected, the instrument stops data collection, displays the flash temperature and prints the record results, stops heating, and the test arm automatically rises, and the experiment ends.

Technical indicators

Measuring range 40~370℃
Accuracy ±1℃ when flash point value <110℃; ±2℃ when flash point value ≥110℃
Repeatability ≤2℃
Resolution 0.1℃
Ambient temperature 5℃~40℃
Relative humidity ≤85%RH (no condensation)
Display method 5.0-inch touch display LCD screen, Chinese display
cooling method Built-in powerful air cooling
printer Thermal type, 36 characters, Chinese character output
voltage AC220V±10% 50Hz±10%
Power consumption ≤600W
Dimensions 350mm×310mm×300mm
Instrument weight 14.5kg

Ordering Guide

    • Accessories Guide

      Oil cup/ignition gun/liquefied steel gas cylinder (gas cylinder connector)

    • Ignition method

      With air source / without air source

  • Precautions

    1. The closed-cup flash point tester should be used in a non-corrosive environment. When replacing the sample, the oil cup must be cleaned.
    2. When not in use, the closed cup flash point tester should be placed in an environment with a temperature of 10-40°C, relative humidity below 80, and no corrosive gases and harmful substances in the air.
    3. When doing the test, the closed cup flash point tester should be placed in a fume hood that can control the air flow independently.
    4. If too much sample is injected into the sample cup, it can be removed with a pipette or other appropriate tools; if the sample sticks to the outside of the instrument, the sample should be poured out, the sample cup should be cleaned, and the sample should be refilled.
    5. Before the experiment, it is necessary to make sure there is no leakage.

Related products

Quick view

Fully automatic open flash point tester TP612

Flash point tester

In stock

Read more

    Sign up To Us Newsletter

    Be the First to Know. Sign up to newsletter today

    Social Links:

    Quick Links

    • Home
    • Products
    • News
    • Case
    • About us
    • Contact us

    Products

    • Online water quality monitoring instrument
    • Laboratory water quality analyzer
    • Laboratory oil analyzer

    Application Cases

    • Power industry
    • Steel Metallurgy
    • Petrochemical Industry
    • Research Institutes
    • Environmental Protection Industry
    • More Industries

    Contact Us:

    • Company address: Room 702, Building 4, No. 39 Linfeng Second Road, Haidian District, Beijing
    • Factory address: 5288 Lekai South Street, Qingyuan District, Baoding City, Hebei Province
    • +86-010-81797160 / +86 133-9165-8253
    • sales@bjtimepower.com
    Copyright 2024 Beijing Shidai Xinwei Measurement and Control Equipment Co., Ltd
    Close
    • Menu
    • Categories
    • Home
    • Products
      • Online water quality monitoring instrument
      • Laboratory water quality analyzer
      • Laboratory oil analyzer
    • Case
      • Power industry
      • Steel and metallurgy
      • Research institutes
      • Environmental protection industry
      • Petrochemical industry
      • More industries
    • News
      • Company News
      • Project News
      • Technical Q&A
    • Contact Us
    • About Us
    Instagram YouTube Pinterest linkedin WhatsApp WhatsApp
    Popular requests:
    • tile
    • wood
    • laminate
    • installation
    • materials