Email To Us

sales@bjtimepower.com

Service Hotline

010-8179-7160

  • Home
  • Products
    • Online water quality monitoring instrument
    • Laboratory water quality analyzer
    • Laboratory oil analyzer
  • Case
    • Power industry
    • Steel and metallurgy
    • Research institutes
    • Environmental protection industry
    • Petrochemical industry
    • More industries
  • News
    • Company News
    • Project News
    • Technical Q&A
  • Contact Us
  • About Us
  • language
    • en_USEnglish
    • es_ESSpanish
    • ko_KRKorean
Menu
Home Laboratory oil analyzer Automatic Potentiometric Titrator TP432
Multifunctional CNC Digester DIS16-B
Back to products
Silicate Monitor TP106
Click to enlarge

Automatic Potentiometric Titrator TP432

Brand: TIMEPOWER

Features: It has automatic liquid suction, automatic liquid injection, and automatic measurement functions.

Application: Suitable for various industries such as environmental protection, chemical engineering, metallurgy, and pharmaceuticals, this product is used for component analysis in various types of potentiometric titrations, including acid-base titration, oxidation-reduction titration, precipitation titration, and complexometric titration.

Share:
  • Description
Description

Features

  • 01 Features automatic liquid aspiration, automatic liquid injection, and automatic measurement functions.
  • 02 A specially designed precision metering pump ensures the accuracy of titration results.
  • 03 With a pH calibration function, it can test the pH of solutions.
  • 04 The three-way conversion valve and hydraulic circuit components are made of special materials.
  • 05 Excellent corrosion resistance ensures long-term continuous operation.
  • 06 The system is well sealed to ensure that no bubbles are generated in the fluid circuit.

Working principle

 Working Principle of Potentiometric Titration Analyzer TP432

  • An automatic potentiometric titrator is an ideal instrument for volumetric analysis in chemical laboratories. Potentiometric titration is a method that determines the titration endpoint by measuring changes in potential during the titration process. Potentiometric titration relies on a sudden change in electrode potential to indicate the endpoint of the titration. Before and after reaching the endpoint, the concentration of the analyte ions in the titrant often changes continuously over several orders of magnitude, causing a sudden change in potential. The concentration of the analyte is still calculated based on the amount of titrant consumed. By using different indicator electrodes, potentiometric titration can be applied to acid-base titration, redox titration, complexometric titration, and precipitation titration.
  • For laboratory applications: potentiometric titration for volumetric analysis; controlled titration of pH values or electrode potentials; manual potentiometric titration for quantitative analysis; pH measurement—for laboratory sampling and determination of the pH value of aqueous solutions; potential measurement—measurement of electrode potentials or other millivolt values.

Technical indicators

Measuring Range  (0 to ±1999) mV    (0.00 to 14.00) pH
Measuring Accuracy 0.1% FS (mV)     ±0.01 pH
Control Accuracy ±3 mV             ±0.03 pH
Input Impedance <10¹² Ω
Operating Temperature (5 to 40) °C
Ambient Humidity  ≤80%RH (no condensation)
Titration Method  Manual or automatically selectable
Stirring Method Magnetic stirring
Power Supply Voltage  AC220V ±10%  50Hz±10%
Dimensions 300mm×280mm×310mm
Weight  3.6 kg

 

Ordering Guide

  • Accessories Guide

After opening the box, please check the model, specifications, and number of accessories of the potentiometric titrator against the packing list.

  • Precautions
  1. If the displayed digits fluctuate erratically, this is typically due to poor power grounding or strong electromagnetic interference in the surrounding environment.
  2. During pH measurements or titration analysis using a glass electrode, if the displayed digits drift and fail to stabilize, this may indicate electrode aging, necessitating timely replacement.
  3. If bubbles appear in the liquid pathway during titration, this is generally caused by the red acrylic tube not being securely tightened, the three-way valve head being loose, the burette being blocked, or the three-way valve not being properly positioned.

Related products

Quick view

Acid Value Tester TP5321

Laboratory oil analyzer

In stock

Read more

    Sign up To Us Newsletter

    Be the First to Know. Sign up to newsletter today

    Social Links:

    Quick Links

    • Home
    • Products
    • News
    • Case
    • About us
    • Contact us

    Products

    • Online water quality monitoring instrument
    • Laboratory water quality analyzer
    • Laboratory oil analyzer

    Application Cases

    • Power industry
    • Steel Metallurgy
    • Petrochemical Industry
    • Research Institutes
    • Environmental Protection Industry
    • More Industries

    Contact Us:

    • Company address: Room 702, Building 4, No. 39 Linfeng Second Road, Haidian District, Beijing
    • Factory address: 5288 Lekai South Street, Qingyuan District, Baoding City, Hebei Province
    • +86-010-81797160 / +86 133-9165-8253
    • sales@bjtimepower.com
    Copyright 2024 Beijing Shidai Xinwei Measurement and Control Equipment Co., Ltd
    Close
    • Menu
    • Categories
    • Home
    • Products
      • Online water quality monitoring instrument
      • Laboratory water quality analyzer
      • Laboratory oil analyzer
    • Case
      • Power industry
      • Steel and metallurgy
      • Research institutes
      • Environmental protection industry
      • Petrochemical industry
      • More industries
    • News
      • Company News
      • Project News
      • Technical Q&A
    • Contact Us
    • About Us
    Instagram YouTube Pinterest linkedin WhatsApp WhatsApp
    Popular requests:
    • tile
    • wood
    • laminate
    • installation
    • materials