Features
- 01 High-resolution color 480×272 touch dot matrix LCD, Chinese and English human-computer dialogue interface.
- 02 8-roller high-precision peristaltic pump, stable and accurate titration.
- 03 High-precision optical inspection system, stable and accurate.
- 04 Automatic fast titration function effectively shortens the measurement time of high acid value samples while ensuring measurement accuracy.
- 05 Built-in KOH concentration calibration, titration volume calibration, blank calibration, optical detection calibration, screen-off protection and other functions.
- 06 Automatically titrate, determine the titration end point, calculate the acid value content and print the test data.
- 07 RS232 and RS485 ports are reserved for communication with computers.
working principle
Working principle of automatic acid value tester TP532
- This method uses toluene-isopropanol reagent to extract the acidic components in the sample, and then titrates with potassium hydroxide-ethanol standard solution. When the end point is reached, the indicator in the extract changes from yellow to green.
- TP532 automatic acid value tester is a The laser transmitter of the laboratory oil analyzer and the automatic acid value tester emits a parallel light beam to hit the sample cup. The sample will absorb this light after changing color, causing the photoelectric model to change, thereby determining the end point.
Technical indicators
| measurement method | Neutralization |
| Measuring range | 0.0001~1.0000 mgKOH/g |
| Resolution | 0.0001 mgKOH/g |
| accuracy | When <0.1000 mgKOH/g, the indication error is ≤ 0.01 mgKOH/g; When ≥0.1000 mgKOH/g, the indication error is ≤ 0.05 mgKOH/g |
| Measuring cups | 6 cups |
| Repeatability | When the value is less than 0.1000 mgKOH/g, the repeatability error is ≤0.01mgKOH /g When the value is greater than 0.1000 mgKOH/g, the weight error is ≤0.05mgKOH/g |
| Power consumption | <100W |
| Ambient temperature | 5℃~35℃ |
| Relative humidity | <80% |
| Communication Port | RS485 、RS232 |
| voltage | AC220V±10%50Hz±10% |
| power | ≤60W |
| Dimensions | 220mm×390mm×220mm |
| Instrument weight | 7 kg |
Ordering Guide
Extraction liquid/neutralization liquid/acid value pump tube
-
Precautions
1. The automatic acid value tester should be used on a flat, clean, dust-free table.
2. After the test, seal the neutralizing liquid to prevent deterioration.
3. Avoid direct sunlight and reduce temperature fluctuations to improve the test accuracy of the instrument.
4. When not in use for a long time, keep the peristaltic pump tube clamp open to prevent the acid value pump tube from being squeezed and deformed for a long time.
5. The automatic acid value tester should be cleaned and maintained in time after testing.
6. If a malfunction occurs, it should be repaired by a technician or returned to the factory for repair. Avoid self-repair to increase losses.