Features
- 01 It adopts imported cold light source, with good optical performance and stable and accurate test.
- 02 The precise quantification of trace reagents is achieved by using a sophisticated infrared quantification system.
- 03 The precise quantification of trace reagents greatly reduces the amount of reagents used.
- 04 The peristaltic pump uses negative pressure to inhale, avoiding corrosion of the pump tube and making reagent mixing simpler and more flexible.
- 05 Peristaltic pump negative pressure suction to avoid corrosion of pump tube
- 06 Imported modified polytetrafluoroethylene transparent hose with a diameter greater than 1.5mm is used to reduce the chance of blockage by water sample particles.
- 07 Support RS232, RS485, 4-20mA data transmission.
- 08 The ammonia nitrogen monitor has multiple measurement modes (continuous sampling, periodic sampling) for customers to choose from.
- 09 The cleaning waste liquid of the ammonia nitrogen monitor is separated from the reaction waste liquid, which is convenient for waste liquid treatment.
- 10 When the ammonia nitrogen monitor is operating normally, there is no workload except adding reagents and standards.
- 11 The ammonia nitrogen monitor uses a high-resolution LCD display module, and all data, status and operation prompts are displayed in Chinese.
working principle
Working principle of ammonia nitrogen monitor TP1112
Ammonia nitrogen monitor TP1112 is an online water quality monitor . After the water sample and masking agent are mixed, ammonia nitrogen in the form of free ammonia or ammonium ions reacts with salicylic acid colorimetric reagent in an alkaline environment and in the presence of a sensitizer to generate a colored complex. The analyzer detects the color change and converts the change into an ammonia nitrogen value for output. The amount of colored complex generated is equivalent to the ammonia nitrogen content.
Technical indicators
| Methodology | HJ/T101-2019 Technical Requirements and Detection Methods for Online Automatic Monitoring Instruments for Ammonia and Nitrogen in Water Quality HJ 536-2009 Determination of Ammonia and Nitrogen in Water Quality |
| Display | 7.0 inch color LCD screen |
| Measuring range | (0-2) mg/L, (0-10) mg/L, (0-50) mg/L, (0-250) mg/L |
| Indication error | ≤±8% (maximum) |
| Repeatability | ±2% |
| Zero drift | ≤0.02mg/L/24h |
| Range drift | ≤1%/24h |
| Lower limit of quantitation | ≤0.15mg/L (indication error ±30%) |
| pH Effect | ±6% |
| Constant temperature time | Adjustable |
| Measuring cycle | The minimum measurement period is 30 minutes |
| Sampling period | Continuous measurement and hourly measurement modes |
| Instrument calibration | Both manual calibration and automatic calibration are possible (automatic calibration time can be set) |
| Maintenance cycle | Usually once a month |
| Output | RS232, RS485, 4-20mA |
| Environmental requirements | Temperature 5~40℃; humidity 65%±20% (no condensation) |
| power supply | AC 220V± 10% , 50Hz± 10% |
| size | 510mm×470mm×1570mm |
| other | Abnormal alarm and power failure will not lose data;
Abnormal reset and power-off reset, the instrument automatically discharges the residual reactants in the instrument and automatically resumes working state |
Ordering Guide
- ●Accessories Guide
Ammonia nitrogen standard solution (500mg/L)/1 bottle; Ammonia nitrogen reagent/1 set (2 types in total); Self-priming pump/1 unit; Waste liquid barrel/2 units; Pure water barrel/1 unit
- ●Precautions
1. When the ammonia nitrogen monitor has obvious faults, users should not open it for repair by themselves, please contact the manufacturer in time.
2. If there is a discrepancy between the instruction manual and the actual operation, the actual situation of the ammonia nitrogen monitor shall prevail.
3. Regularly check the amount of waste liquid in the waste liquid barrel and handle it in time to avoid overflow of waste liquid.